| ¡ö |
This intelligent controller, adopting function block programming, having large programming capacity, being f reely |
| |
fprogrammed according to different users and different fields, can run at your desired time table and the RTC |
| |
accuracy can reach second and makes your time control more accurate. And up to 128 time sessions can |
| |
be set , especially suitable for time-control system. |
| ¡ö |
Safety password function makes your program
absolutely safe. Before writing program, password can be set. And only |
| |
after entering the correct password,
can the program be modified. |
| ¡ö |
It is equipped with a removable, convenient and programmable LCD, providing 64 friendly human-machine interfaces, |
| |
32 virtual keys, having the function to display the alarming message and parameter and to modify the parameter. |
| |
When needed, it can be installed. And when not needed, it can be removed and replaced with an
ordinary front panel. |
| |
Thus the cost will be greatly reduced. |
| ¡ö |
The input can receive not only the digital input but also the analogue input to perform the control and . transmission of |
| |
fthe temperature, moisture, pressure, flow level unit and so on. |
| ¡ö |
It has well-featured and
compact design with 12 point input and 8 point output. Equipped with expansion module, it can |
| |
be expanded into
82 I/O better ,and to MAX 122I/O.It can be connected with telephone voice module and remote control |
| |
module to perform the notification and alarming function. And the connection between the host and the module can |
| |
be Bridge SR-CBA or flexible
connection SR-ECBA. |
| ¡ö |
The machine has short-circuit protection (internal) and relay output protection (external) function, which makes your |
|
usage safer and easier. |
| |
|
| |
 |
| Power supply |
Power |
DC12V-24V |
| Input parameters: |
Input No |
12(X0-A7,Y0-Y3) |
Digital input |
12(X0-A7,Y0-Y3) |
Analogue input |
None |
Power range |
DC0-24V |
Input signal0 |
DC0-5V |
Input signal1 |
DC10-24V |
| Output parameters: |
Output No |
8(QX0-QX7) |
Output type |
Transistor (NPN)output |
Output voltage |
DC0-24V |
Output current |
2A |
| Environment temperature: |
Running temperature |
0¡æ¡«55¡æ |
Storage/shipment |
-40¡æ¡«70¡æ |
| Switch frequency: |
Mechanism |
10Hz |
Resistor/light load |
2Hz |
Sensitive load |
0.5Hz |
| Other parameters: |
Clock buffer memory at 25¡æ |
80h |
RTC accuracy |
Max¡À5s/day |
Protection |
IP20 |
Emission on line |
EN55011(B) |
The main frequency range |
47-63Hz |
Function block No |
128¸ö |
Program storage capacity |
64K |
Isolation intensity |
IEC1131 |
|
 |
 |
| |